Bulletin M-2.1
General Description: Ordering Instructions:
* Machine Type Transformer * Order by model number shown
* Stacked Core * Add "X" to model number if transformer is to be fully potted
* Frame Cross Section 10 3/4" X 13 3/8" * Specify "primary conduit opening" or "primary cable clamp
block" ("primary conduit opening" furnished standard)
KVA Rating Secondary No. of Tap Switch RWMA Model Number Weight Dwg. Frame Turns Ratio 440 Volt
110 C Rise Voltage Taps Location Pad Size 220V/60 Hz 440V/60 Hz Approx. No. Letter Tap 1 Tap 2 Tap 3 Tap 4 Tap 5 Tap 6 Tap 7 Tap 8
        1 M226100ML1BML M446100ML1BML 420                    
      End Mount 2 M226100ML1BNL M446100ML1BNL 423 R1471                  
100 5.5 to 10.0 8   3 M226100ML1BOL M446100ML1BOL 427   ML 80:1 74:1 68:1 62:1 57:1 52:1 48:1 44:1
  Volts     1 M226100ML1FML M446100ML1FML 440                    
      Side Mount 2 M226100ML1FNL M446100ML1FNL 443 R1472                  
        3 M226100ML1FOL M446100ML1FOL 447                    
        1 M226125MA1BML M446125MA1BML 490                    
      End Mount 2 M226125MA1BNL M446125MA1BNL 493 R1471                  
125 6.6 to 12.2 8   3 M226125MA1BOL M446125MA1BOL 501   MA 66:1 60:1 55:1 50:1 46:1 42:1 39:1 36:1
  Volts     1 M226125MA1FML M446125MA1FML 510                    
      Side Mount 2 M226125MA1FNL M446125MA1FNL 513 R1472                  
        3 M226125MA1FOL M446125MA1FOL 517                    
Standard Features: Optional Features:
* Class "F" insulation * Voltages and frequencies other than shown available on request
* Solderless lug connections for primary wiring * Thermostats
* Secondary pad sizes and hole spacings to RWMA * Special secondary pad sizes available on request
standard * Remote tap switch
* Secondary end positively sealed against
contimination