| Bulletin M-4 | ||||||||||||||||
| General Description: | Ordering Instructions: | |||||||||||||||
| * Machine Type Transformer | * Order by model number shown | |||||||||||||||
| * Stacked Core | * Add "X" to model number if transformer is to be fully potted | |||||||||||||||
| * Frame Cross Sections: | ||||||||||||||||
| for V & VA frames 13 3/8" X 20 3/4" | ||||||||||||||||
| for U & UA frames 16 1/2" X 20 3/4" | ||||||||||||||||
| KVA Rating | Secondary | No. of | Tap Switch | RWMA | Model No. | Weight | Dwg. | Frame | Turns Ratio 440 V | |||||||
| 110 C Rise | Voltage | Taps | Location | Pad Size | 440V/60 Hz | Approx. | No. | Letter | Tap 1 | Tap 2 | Tap 3 | Tap 4 | Tap 5 | Tap 6 | Tap 7 | Tap 8 |
| 250 | 7.6 to 13.8 | 8 | End Mount | 3 | M446250V1BOL | 975 | R1286 | V | 58:1 | 53:1 | 49:1 | 45:1 | 41:1 | 38:1 | 35:1 | 32:1 |
| Volts | ||||||||||||||||
| 300 | 8.6 to 15.7 | 8 | End Mount | 3 | M446300VA1BOL | 1085 | R1286 | VA | 51:1 | 47:1 | 43:1 | 39:1 | 36:1 | 33:1 | 30:1 | 28:1 |
| Volts | ||||||||||||||||
| 300 | 8.6 to 15.7 | 8 | End Mount | 4 | M446300VA1BPL | 1100 | R1286 | VA | 51:1 | 47:1 | 43:1 | 39:1 | 36:1 | 33:1 | 30:1 | 28:1 |
| Volts | ||||||||||||||||
| 400 | 8.8 to 16.9 | 8 | End Mount | 4 | M446400U1BPL | 1465 | R1285 | U | 50:1 | 46:1 | 42:1 | 38:1 | 34:1 | 31:1 | 28:1 | 26:1 |
| Volts | ||||||||||||||||
| 500 | 9.8 to 18.3 | 8 | End Mount | 4 | M446500UA1BPL | 1545 | R1285 | UA | 45:1 | 41:1 | 37:1 | 34:1 | 31:1 | 28:1 | 26:1 | 24:1 |
| Volts | ||||||||||||||||
| Standard Features: | Optional Features: | |||||||||||||||
| * Class "F" insulation | * Voltages and frequencies other than shown available on request | |||||||||||||||
| * Stud connections for primary wiring | * Thermostats | |||||||||||||||
| * Secondary pad sizes and hole spacings to RWMA | * Special secondary pad sizes available on request | |||||||||||||||
| standard | * Remote tap switch | |||||||||||||||
| * Secondary end positively sealed against | ||||||||||||||||
| contimination | ||||||||||||||||